Free calculator

Sauna Heater Size Calculator

Measure the inside of your sauna room and enter any glass, tile or log walls. The calculator works out the volume, applies each maker's own allowance and lists the Harvia, HUUM and Homecraft heaters whose published room range covers it, with the document each figure comes from.

Your sauna room

Inside dimensions, ft

Measure the hot room on the inside, paneling to paneling and floor to ceiling. Benches do not count against the volume.

Surfaces that soak up heat, ft²

Only surfaces with no insulation behind them. A 24 × 80 in full-glass door is about 13 ft² (1.2 m²).

Most US houses have 240 V single-phase service. Apartment buildings and commercial spaces often have 208 V. Ask your electrician if you are not sure.

What the makers' tables say

Room volume

–

Matching heaters

–

    Sauna heater size chart: published room ranges

    Every heater in the calculator, with the room range, breaker and supply wire exactly as the maker's document gives them. Ranges are for a fully insulated room; see the allowances below for glass and masonry. A star marks a cubic meter figure we converted from the maker's cubic feet. Checked November 21, 2026.

    Harvia Finland

    Harvia sauna heaters: output, room volume range, breaker and wire size as published
    Heater Supply Output Room, ft³ Room, m³ Breaker or fuse Wire Listing Source
    KIP60B 240 V 6 kW 169–300 4.8–8.5 * min. 25 A (or 2 groups, min. 16.7 A) 10 AWG UL Technical data
    KIP80BShown as unavailable on the US page 240 V 8 kW 251–424 7.1–12 * min. 33.4 A (or 2 groups, min. 22.3 A) 8 AWG UL Technical data
    The Wall SW45Not in the calculator: no US listing 230 V 4.5 kW 106–212 3–6 * 25 A at 230 V 1N~; 3 x 10 A at 400 V 3N~ – CE, EAC (no UL mark listed) Technical data

    HUUM Estonia

    HUUM sauna heaters: output, room volume range, breaker and wire size as published
    Heater Supply Output Room, ft³ Room, m³ Breaker or fuse Wire Listing Source
    DROP 4 240 V 4.5 kW 106–248 3–7 30 A18.75 A drawn 10 AWG SGS Listed Table 2
    DROP 6 240 V 6 kW 177–318 5–9 30 A25 A drawn 10 AWG SGS Listed Table 2
    DROP 7 240 V 7.5 kW 248–389 7–11 40 A31.25 A drawn 8 AWG SGS Listed Table 2
    DROP 9 240 V 9 kW 283–460 8–13 50 A37.5 A drawn 8 AWG SGS Listed Table 2
    DROP 4 208 V 3.4 kW 89–177 2.5–5 20 A16.35 A drawn 10 AWG SGS Listed Table 3
    DROP 6 208 V 4.5 kW 142–248 4–7 30 A21.63 A drawn 10 AWG SGS Listed Table 3
    DROP 7 208 V 5.6 kW 177–301 5–8.5 30 A26.92 A drawn 8 AWG SGS Listed Table 3
    DROP 9 208 V 6.75 kW 212–354 6–10 40 A32.44 A drawn 8 AWG SGS Listed Table 3

    Homecraft Canada

    Homecraft sauna heaters: output, room volume range, breaker and wire size as published
    Heater Supply Output Room, ft³ Room, m³ Breaker or fuse Wire Listing Source
    Revive Slim 4 kW 240 V 4 kW 100–150 2.8–4.2 * 30 A 10 AWG CSA/UL (maker's statement) 240V heaters table
    Revive Slim 5 kW 240 V 5 kW 100–250 2.8–7.1 * 30 A 10 AWG CSA/UL (maker's statement) 240V heaters table
    Revive / H-Series 6 kW 240 V 6 kW 200–325 5.7–9.2 * 40 A 8 AWG CSA/UL (maker's statement) 240V heaters table
    Revive / H-Series 7.5 kW 240 V 7.5 kW 250–370 7.1–10.5 * 40 A 8 AWG CSA/UL (maker's statement) 240V heaters table
    Revive / H-Series 9 kW 240 V 9 kW 325–450 9.2–12.7 * 50 A 8 AWG CSA/UL (maker's statement) 240V heaters table
    Apex 10 kW 240 V 10 kW 400–625 11.3–17.7 * 50 A 8 AWG CSA/UL (maker's statement) 240V heaters table
    Revive 6 kW 208 V, 3-phase 6 kW 200–325 5.7–9.2 * 30 A16.7 A drawn 8 AWG CSA/UL (maker's statement) 208V heaters (3 phase) table
    Revive 7.5 kW 208 V, 3-phase 7.5 kW 250–370 7.1–10.5 * 30 A20.8 A drawn 8 AWG CSA/UL (maker's statement) 208V heaters (3 phase) table
    Revive / H-Series 9 kW 208 V, 3-phase 9 kW 325–450 9.2–12.7 * 40 A25 A drawn 8 AWG CSA/UL (maker's statement) 208V heaters (3 phase) table
    Apex 12 kW 208 V, 3-phase 12 kW 425–700 12–19.8 * 50 A33.4 A drawn 6 AWG CSA/UL (maker's statement) 208V heaters (3 phase) table
    Apex 15 kW 208 V, 3-phase 15 kW 550–900 15.6–25.5 * 60 A41.7 A drawn 6 AWG CSA/UL (maker's statement) 208V heaters (3 phase) table
    Apex 18 kW 208 V, 3-phase 18 kW 690–1,200 19.5–34 * 60 A48 A drawn 6 AWG CSA/UL (maker's statement) 208V heaters (3 phase) table

    What size heater for common sauna rooms

    Inside dimensions with a 7 ft ceiling, fully insulated, no glass, on 240 V single-phase. Each cell lists the heaters whose published range includes the room. Harvia's column also gives what its own online calculator suggests, which is a separate rule of 0.7 kW per cubic meter.

    Heaters whose published room range covers common sauna room sizes, by maker
    Room Volume Harvia HUUM Homecraft
    4 × 4 ft 112 ft³3.2 m³ None listed Calculator: 2.3 kW DROP 4 (4.5 kW) Revive Slim 4 kW, Revive Slim 5 kW
    4 × 5 ft 140 ft³4 m³ None listed Calculator: 2.8 kW DROP 4 (4.5 kW) Revive Slim 4 kW, Revive Slim 5 kW
    4 × 6 ft 168 ft³4.8 m³ None listed Calculator: 3.3 kW DROP 4 (4.5 kW) Revive Slim 5 kW
    5 × 6 ft 210 ft³5.9 m³ KIP60B (6 kW) Calculator: 4.2 kW DROP 4 (4.5 kW), DROP 6 (6 kW) Revive Slim 5 kW, Revive / H-Series 6 kW
    6 × 6 ft 252 ft³7.1 m³ KIP60B (6 kW), KIP80B (8 kW) Calculator: 5 kW DROP 6 (6 kW), DROP 7 (7.5 kW) Revive / H-Series 6 kW, Revive / H-Series 7.5 kW
    6 × 7 ft 294 ft³8.3 m³ KIP60B (6 kW), KIP80B (8 kW) Calculator: 5.8 kW DROP 6 (6 kW), DROP 7 (7.5 kW), DROP 9 (9 kW) Revive / H-Series 6 kW, Revive / H-Series 7.5 kW
    6 × 8 ft 336 ft³9.5 m³ KIP80B (8 kW) Calculator: 6.7 kW DROP 7 (7.5 kW), DROP 9 (9 kW) Revive / H-Series 7.5 kW, Revive / H-Series 9 kW
    7 × 8 ft 392 ft³11.1 m³ KIP80B (8 kW) Calculator: 7.8 kW DROP 9 (9 kW) Revive / H-Series 9 kW
    8 × 8 ft 448 ft³12.7 m³ None listed Calculator: 8.9 kW DROP 9 (9 kW) Revive / H-Series 9 kW, Apex 10 kW
    8 × 10 ft 560 ft³15.9 m³ None listed Calculator: 11.1 kW None listed Apex 10 kW

    "None listed" means none of the heaters in our data covers that volume, not that the maker has nothing for it. Harvia, for one, sells more heaters in the US than the two we have checked.

    Glass, tile and log walls: how each maker adjusts

    Uninsulated surfaces take heat out of the air, so makers ask you to size for a bigger room. They do not use the same figure, and the calculator applies each maker's own rule to that maker's heaters.

    Harvia

    +1.2 m³ per m²

    About 3.9 ft³ per ft²; +1.5 m³ (53 ft³) for a glass door; log walls × 1.5

    Harvia's calculator multiplies the room volume by 1.5 for log walls, adds 1.5 m³ for a glass door, and adds 1.2 m³ for each m² of non-insulated wall. It then suggests 0.7 kW per m³, at least 2.3 kW.

    Harvia does not publish this rule as text. The page says only that windows and heat-storing surfaces such as brick, concrete or massive logs raise the power needed; the numbers come from the calculator's script. The support article quoted elsewhere for the same rule was not reachable.

    Source · checked November 21, 2026

    HUUM

    +3.3 ft³ per ft²

    1 m³ per m² of brick, tile or glass

    In case there are any uninsulated brick, tile, or glass walls in the sauna room, an additional 3.3 ft³ must be added to the sauna room volume for each 1 ft² of such wall; or 1 m³ for each 1 m².

    The manual names brick, tile and glass only. HUUM's online calculator lists log walls among the uninsulated surfaces but does not publish the figure it uses.

    Source · checked November 21, 2026

    Homecraft

    No figure

    The manual's table is for the room as built

    The manual we read gives room sizes in cubic feet and no allowance for glass, tile, stone or log walls.

    Source · checked November 21, 2026

    How the calculator works

    It multiplies length by width by height for the room volume. For each maker it then adds that maker's own allowance for glass, masonry and log walls, where the maker publishes one, and lists that maker's heaters whose published room range includes the result. It does not pick a heater for you or blend the makers' rules into one of ours.

    • Overlap. When two heaters from the same maker both cover the room, both are shown. Makers' ranges overlap on purpose.
    • Between sizes. When the room falls in a gap, or near the top or bottom of the only matching range, the result says so and names the neighbor.
    • Voltage. A heater's range depends on its output. HUUM's DROP heaters put out less on 208 V, so the same model covers a smaller room; Homecraft publishes a separate three-phase 208 V table. None of the heaters in our data runs on 120 V.
    • Outdoors. None of the documents we read changes the room ranges for an outdoor sauna. Homecraft specifies an outdoor contactor box, and HUUM's online calculator asks indoor or outdoor without saying what it changes. Expect longer heat-ups in winter; no maker we read puts a number on it.

    Everything runs in your browser. Nothing you type is sent to us or anyone else; "Copy link" puts the numbers in the page address so you can share or bookmark them.

    Our guide to sizing a sauna heater explains the ranges, wood-burning stoves and what to do between sizes.

    Sources

    Not in the calculator yet

    • Saunum, Finnleo and TyloHelo, and Amerec. We found their sizing tables only on dealers' pages. They go in once we have the makers' own manuals.
    • More Harvia models. Only the KIP60B and KIP80B are checked so far. The Wall SW45 appears in the chart for comparison but carries no US listing on Harvia's US page.
    • Wood-burning stoves. Their makers size them differently, and they are not part of this calculator.

    Questions people ask

    What size heater do I need for a 5 x 6 ft sauna?

    With a 7 ft ceiling the room is 210 cubic feet. On 240 V that falls inside the published ranges of the HUUM DROP 6 (177 to 318 ft³), the Harvia KIP60B (169 to 300 ft³) and Homecraft's 5 kW Revive Slim (100 to 250 ft³) and 6 kW heater (200 to 325 ft³). Glass or tile in the room moves the figure up.

    How much bigger a heater does a glass door need?

    It depends on the maker. HUUM's US manual adds 3.3 cubic feet of room for each square foot of uninsulated glass, tile or brick. Harvia's online calculator adds 1.5 cubic meters, about 53 cubic feet, for a glass door. Homecraft's manual gives no figure.

    Can a sauna heater run on a 120 V outlet?

    None of the traditional heaters in our data does: every Harvia, HUUM and Homecraft model we checked needs a 240 V or 208 V circuit. Plug-in 120 V units are mostly infrared cabins.

    Does a sauna heater need a GFCI breaker?

    Ask your electrician and inspector. HUUM's US manual recommends connecting the DROP without a GFCI breaker, and Homecraft's manual says a GFI breaker usually will not work with a sauna heater and to check with the local inspection authority.